บ้าน ผลิตภัณฑ์AC Contactor

L2 series 2pole and 4pole residual current circuit breakers

ได้รับการรับรอง
จีน Shenzhen City Breaker Co., Ltd. รับรอง
จีน Shenzhen City Breaker Co., Ltd. รับรอง
Excellent quality and fast delivery.

—— Victor

I want to say that your products very good. Thank you for all your suggestion, also good after sales service.

—— Mr Abílio Cipriano

Easy to talk with, very professional and fast service, the flag quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

สนทนาออนไลน์ตอนนี้ฉัน

L2 series 2pole and 4pole residual current circuit breakers

L2 series 2pole and 4pole residual current circuit breakers
L2 series 2pole and 4pole residual current circuit breakers L2 series 2pole and 4pole residual current circuit breakers L2 series 2pole and 4pole residual current circuit breakers L2 series 2pole and 4pole residual current circuit breakers

ภาพใหญ่ :  L2 series 2pole and 4pole residual current circuit breakers

รายละเอียดสินค้า:
Place of Origin: Wenzhou China
ชื่อแบรนด์: OEM,HVIZ
ได้รับการรับรอง: SEMKO,CE CB
Model Number: L2-63
การชำระเงิน:
Minimum Order Quantity: 500pcs
ราคา: Negotiable
Packaging Details: standard exporting box
Delivery Time: 15-30 days
Payment Terms: T/T,Paypal,,moneygram,L/C at sight
Supply Ability: 300.000pcs/month
รายละเอียดสินค้า
แสงสูง:

residual current circuit breaker

,

RCCB

,

earth leakage circuit breaker

L2 residual current circuit breaker

1.Application scope ofL2 residual current circuit breaker

L2-63 Residual Current Circuit Breaker provide the function of isolation switching and earth leakage protection of electrical circuits.And also provide the indirect protection of the electric current and provide the protection of the fire caused by the electrical circuit fault.

1.In compliance with IEC/EN60898-1.

2.Bilateral busbar wiring capalilities to adapt tothe wider use of permises.

3.Leading in electronic driven,more cost-effectively.

4.Maximum connecting ability of 25mm²,wiring torque 3Nm,applicable to a variety of installing equipments,wiring stronger.

5.Protection class:IP20

2.Technical Data ofL2 residual current circuit breaker

StandardIEC/EN 60898-1

Electrical

features

Rated current inA16 25 40 63 80 100
Poles2P 4P
Rated voltage UeV230/400
Insulation coltage UiV500
Rated frequencyHz50/60Hz
Rated residual making and breaking capacity ImA0.03 0.1 0.3
Rated impulse withstand voltage (1.2/50)UipmV6000
Dielectric test voltage at and ind.Freq.for 1minKV2.5
Pollution degree2
Break time under InS≤0.1

Mechanical

features

Electrical life4000
Machanical life8000
Fault current indicatorYes
Protection degreeIP 20
Reference temperature of setting of thermal element°C30
Ambient temperature(with daily average≤35°C)°C-5~+40
Storage temperature°C-25...+70
InstallationTerminal connection typeCable/U-type busbar/Pin-type busbar
Terminal size top/bottom for cable

mm²

AWG

25

18-3

Terminal size top/bottom for busbarmm²

AWG

25

18-3

Tightening torque

N*m

In-lbs.

2.5

22

Mounting

OnDIN rail FN 60715(35mm)

by means of fast clip device

ConnectionFrom top